Save Costs with Decentralized Periphery from Pilz!
January 7, 2025
For cabinet-free installation with IP67 modules
With the PDP67 modules, Pilz offers solutions for decentralized applications directly in the field. The modules have protection type IP67, meaning they are resistant to dirt and water. The decentralized modules optimize installation and wiring work. They save time, money and space in the control cabinet.
As they are integrated into dirt and water-repellent IP67 housings, the PDP67 modules reliably ensure safety even in rugged industrial environments.
You will find the required cable, connector and adapter accessories under connection technology.
Connect safe sensors directly
PDP67 modules are used directly in the field, and forward signals from the sensors connected decentrally in the field to the safe small controller PNOZmulti 2.
Pilz is expanding its product portfolio for decentralised applications with the input and output modules PDP67 F 10DI4DO 5/8 ION (VA). The PDP67 modules have ten safe digital inputs and, as a new feature, have four safe semiconductor outputs, which enable the modular safety gate system PSENmlock to be connected directly, for example. You configure your safety circuit in the software tool PNOZmulti Configurator. You can connect up to four of the modules with protection type IP67 to the PNOZmulti 2 via the link module PNOZ m EF PDP-Link.
Up to four safe sensors per PDP67 module – so a total of up to 64 sensors– can be monitored flexibly in the field in this way. A version with stainless steel screw connections is available, for use in the food industry. M12 plug-in connectors, two 5-pin and two 8-pin, link sensors and actuators quickly and easily to the PDP67 module.
- Complicated wiring is avoided
- Reduces costs when expanding and commissioning modular production plants
Save costs with decentralized periphery!
The new decentralized input and output module PDP67 F 8DI4DO 5/5 ION can be parameterized from software version 11.4.0 of the PNOZmulti Configurator and has eight safe digital inputs and four safe semiconductor outputs. Eight outputs are configurable as standard, test pulse or 24 V. Possible connections are four 5-pin M12 plug-in connectors for direct connection of coded safety gate switches PSENcode or safety light curtains PSENopt II, for example. The version PDP67 F 8DI4DO 5/5 VA ION with stainless steel screw connections is available for use in the food industry.
Decentralized safety for modular plants
Flexible and modular automation solutions require I/O systems that offer personnel and process protection directly at the point of danger. The new PDP67 PN with Profinet/Profisafe interface enables exactly that. Thanks to the IP67 protection type and robust zinc housing it is ideal for positioning on the machine, outside of the control cabinet. It provides reliable safety even at temperatures of -30°C to 70°C!
The I/O module is simple to configure and can easily be integrated into existing Profinet/Profisafe networks. The absence of control cabinets and the use of simple M12 plug-in connectors reduces the wiring work significantly. That saves time during commissioning and enables modular production plants to be expanded with ease. Thanks to universal connections, which can be configured as both inputs and outputs, users only need to keep one type of PDP67 PN in stock. That saves additional space in the warehouse!
Simple installation of IP67 modules – Your benefits
- Less planning and design work, thanks to simple installation
- No control cabinet necessary
- Enables a modular machine concept
- Can be used up to protection type IP67
- Reduced wiring
Features of IP67 modules
- Reduced wiring due to plug-and-play with standardised M12 plug-in connections
- Installation almost anywhere due to compact and robust housing
- Decentralised installation of safety-related, digital sensor and actuator technology
- Simple configuration due to proven PILZ tools
- Integrated web server for rapid fault diagnostics (PDP67 PN)
- Universally configurable, safe inputs/outputs (PDP67 PN)
- Application in heights up to 5,000 m
Features / products | Passive junction PDP67 F 4 code | Digital input modules PDP67 F 8DI ION (VA) | Decentralised input modules PDP67 F 8DI ION PT | Decentralised input and output modules PDP67 F 10DI4DO 5/8 ION (VA) | Decentralised input and output modules PDP67 F 8DI4DO 5/5 ION (VA) | Profinet/Profisafe modules PDP67 PN |
---|---|---|---|---|---|---|
Order number | 773603773613 – with stainless steel screw connection | 773600773614 – with stainless steel screw connection | 773616 | 772610772611 – with stainless steel screw connection | 772600772601 – with stainless steel screw connection | 4R000001 |
Bus protocol | – | IO net p | IO net p | IO net p | IO-net p | Profisafe / Profinet |
Cascadable | – | |||||
Plug-and-play M12 connector | ||||||
Diagnostic LED | ||||||
Configuration | – | PNOZmulti Configurator | PNOZmulti Configurator | PNOZmulti Configurator | PNOZmulti Configurator | PASconfig |
Number of inputs and outputs | 4 Inputs | 8 safe inputs / standard outputs, configurable | 8 safe inputs / standard outputs, configurable | 10 safe inputs / 4 safe semiconductor outputs; 8 outputs configurable as standard, test pulse or 24 V; connections 2 x M12 5-pin and 2 x M12 8-pin | 8 safe inputs / 4 safe semiconductor outputs, 8 outputs configurable as standard, test pulse or 24 V outputs, 4 x 5-pin M12 female connector. | Up to 12 safe digital inputs (configurable), up to 6 safe digital outputs (configurable), 2 safe digital outputs, 2-pin |
Housing | Plastic | Plastic | Plastic | Plastic | Plastic | Die-cast zinc |
Connection | PSENcodePSENslock | Configurable safe small controllers PNOZmulti | Configurable safe small controllers PNOZmulti | Configurable safe small controllers PNOZmulti 2 | Configurable safe small controllers PNOZmulti 2 | Any Profinet/Profisafe controller |
Decentralized and passive – decentralized safety
Enable simple configuration and installation in Profinet/Profisafe networks. They expand our PDP product range and can be integrated into the network of remote I/O systems PSSuniversal 2. Sensors as well as actuators can be connected to an IP67 device thanks to flexibly configurable I/O ports. As such the device is highly flexible for use in the most diverse applications. It also simplifies your stockholding! Thanks to the robust, zinc housing it withstands temperatures of -30° to 70°C.
The enables the connection of up to four sensors PSENslock or PSENini. As well as being able to connect to the configurable control systems PNOZmulti, PNOZmulti Mini and PNOZmulti 2, safety relays PNOZsigma are also available.
Digital PDP67 modules with protection type IP67 forward signals from the sensors connected decentrally in the field to the evaluation device on the small controllers PNOZmulti 2. Up to 64 sensors and actuators can be connected. Complicated wiring is avoided. That way you reduce costs during commissioning and when expanding your machinery and production plants.
Industry uses – Wherever decentralization plays an important role
Pilz’s product range: IP67 modules
I/O Net p modules
The decentralised input and output modules PDP67 in protection type IP67 monitor safety functions directly in the field. They are connected to the safe small controller PNOZmulti 2 and their parameters are set in the software tool PNOZmulti Configurator. Communication is via a safe data link.
Passive junction
Passive junctions optimise your installation and wiring effort by removing the need for additional, cost-intensive hardware. Up to 4 PSENcode units can be connected to any evaluation device (PNOZ X, PNOZsigma) via the passive junction, using M12 connection technology.
Accessories for IP67 modules
Various accessories are available, such as connection cables and adapters.
PDP67 PN with Profinet/Profisafe interface
Flexible and modular automation solutions require I/O systems that offer personal and process protection directly at the point of danger. The new PDP67 PN with Profinet/Profisafe interface enables exactly that.
More Information
Related Story
Training Courses on Plant and Machinery Safety from Pilz
Plant safety is vitally important for the safe operation of technical plants. As a machine manufacturer or operator you are legally obliged to ensure the safety of plant, machinery and devices. Training courses teaches you to identify risks and avoid accidents. Further training for safety officers and employees is the key to success here. With this knowledge you can operate plants more efficiently and safely carry out maintenance work. By integrating plant safety into your company you are demonstrating responsibility and increasing the confidence of authorities, employees and the public. Plant safety also contributes towards the prevention of environmental pollution and damage.