7 Top Tips for Cooling IT Equipment

July 17, 2024

7 Top Tips for Cooling IT Equipment

As the world becomes increasingly digitalized, with a growing reliance on high-performing and reliable IT equipment, effective hardware management is essential to facilitate rapid access to large amounts of data and its analytics. The upkeep of IT infrastructure, including maintaining appropriate temperatures, ensures the reliability and security of data and minimizes the risk of system failures. In this article, Rittal explores some effective strategies to keep your IT equipment cool.

1. Optimize the Room Temperature 

If the ambient air temperature becomes too high, it can have a detrimental effect on your IT equipment, forcing the internal fans to work harder to keep it cool. Aim to maintain a controlled room temperature between 18-27°C to prevent overheating while ensuring energy efficiency.

2. Implement Aisle Containment 

Aisle containment in a data centre is a design strategy used to efficiently manage airflow. It involves organizing server racks in alternating rows with cold air intakes facing one aisle (the cold aisle) and hot air exhausts facing the opposite aisle (the hot aisle). This arrangement helps to separate the cold air supplied to the equipment from the hot expelled air, improving cooling efficiency, reducing energy consumption, and lowering cooling costs.

3. Utilize Blanking Panels 

Installing blanking panels in empty rack spaces is crucial to optimize cooling in server environments, as it helps to direct airflow through the equipment and prevents the recirculation of hot air, thereby maintaining a more consistent and controlled temperature. Additionally, implementing air baffling kits within the racks can further maximize cooling efficiency by effectively separating the cold intake and hot exhaust air paths, ensuring that the cooling systems work more effectively and energy-efficiently.

4. Improve Cable Management 

Proper cable management is vital to suppress the temperature in server rooms, as structured cabling can have an adverse effect on airflow, causing equipment to overheat. To overcome this problem, cable management solutions can optimize the flow of air within IT racks, preventing the build-up of heat around the equipment.

5. Implement Temperature Monitoring 

Temperature and climate monitoring systems allow you to track ambient environmental conditions in real-time, so that prompt action can be taken to reduce the temperature if it exceeds acceptable limits. Automated alerts can notify you of any sudden changes that might lead to overheating.

6. Consider Inline Cooling 

Advanced cooling technologies, such as inline liquid cooling, can be more efficient than traditional air-cooling methods as they place the cooling unit next to the heat source for optimum cooling performance.

7. Schedule Regular Maintenance 

Regular maintenance of cooling systems, including cleaning air filters, checking for leaks, and ensuring the proper operation of cooling units, is essential to prevent problems that could cause the ambient temperature to rise and cooling techniques to fail when they are most needed.

Advanced Cooling Solutions from Rittal 

Rittal offers a comprehensive range of climate control solutions tailored to the needs of modern data centres. These solutions include:

  • Precision Climate Control Units: Ensure accurate temperature and humidity control, essential for high-performance computing environments.
  • Turnkey Cooling Containers: Provide flexible and scalable cooling solutions for data centres of all sizes.
  • Atmospherically Sealed Chiller Systems: Offer reliable cooling with high energy efficiency.

Conclusion 

Effective cooling strategies are crucial for maintaining the performance and longevity of IT equipment. By implementing these tips and leveraging advanced cooling solutions from Rittal, businesses can ensure their IT infrastructure remains reliable and efficient, minimizing the risk of system failures and optimizing energy use.

Source

Related Story

Enhancing Efficiency and Sustainability with Rittal’s New Blue e+ S Cooling Units

The push towards sustainable manufacturing is driving the need for efficient enclosure cooling units, especially in industries like automotive where consistent cooling is crucial. The challenge lies in maintaining necessary cooling outputs while adhering to eco-friendly standards.

Related Articles


Latest Articles

  • How the NX102 Controller Streamlines Machine Automation with EtherCAT and CIP Safety

    November 12, 2024 In today’s manufacturing landscape, the complexity of machine control systems often leads to increased costs, extended implementation times, and challenging maintenance requirements. Omron’s NX102 Machine Automation Controller addresses these challenges head-on by seamlessly integrating EtherCAT motion control and CIP Safety functionality into a single, powerful platform. Simplified Network Architecture Through Integration The NX102 controller… Read More…

  • 3 Things Manufacturers Should Know About Industry 5.0

    November 12, 2024 While many manufacturers are still embracing the principles of Industry 4.0, the next evolution, Industry 5.0, is already beginning to take shape. Unlike Industry 4.0, which was a giant leap forward in automation and digitalization, Industry 5.0 represents a reconsideration of how smart technology platforms can work alongside humans. This includes technologies like artificial intelligence (AI), the Industrial… Read More…


Featured Article

Revolutionizing Material Movement with Autonomous Mobile Robots

Revolutionizing Material Movement with Autonomous Mobile Robots

In today’s fast-paced manufacturing and logistics industries, the need for efficient and flexible material movement solutions has never been greater. Traditional methods like conveyor systems, forklifts, and manual pushcarts have served us well, but they come with limitations.

That’s why Omron is thrilled to announce the launch of their game-changing MD Series of Autonomous Mobile Robots (AMRs). Read more


Products

  • FLO Confirms FLO Station Eligibility for ZEVIP Funding in 2024

    November 21, 2024 FLO confirms that all FLO commercial charging stations remain eligible for ZEVIP funding under this new federal directive Canada recently announced trade measures impacting vehicles from China and limiting eligibility under the Natural Resources Canada (NRCan) Zero Emission Vehicle Infrastructure Program (ZEVIP) to electric vehicle (EV) charging products manufactured in countries that have negotiated free… Read More…

  • Omron’s D40A-2 Non-Contact Interlock Door Switch

    November 21, 2024 Next-generation, non-contact safety interlock switch for most common safety applications. The D40A-2 Non-Contact Safety Door Switch is designed to enhance safety and efficiency in industrial environments. This advanced switch exceeds safety standards and is ideal for manufacturing settings, featuring a coded magnetic mechanism that improves reliability and prevents bypassing. It includes 2-color… Read More…